Goodrive350-19 series VFD for crane
Function
Name
code
macros
Enabling
P90.04
brake-oriented
logic
Enabling forward
torque for
P90.05
reverse-running
start/stop
Description
When the S terminal selects function 35 and
takes effect, and P90.03=1, the macro
parameter is switched from P90.00 to P90.01,
and motor parameters are automatically
switched.
2: Switch from motor 1 to motor 3
When the S terminal selects function 88 and
takes effect, and P90.03=2, the macro
parameter is switched from P90.00 to P90.01,
and motor parameters are automatically
switched.
3: Switch from the master to the slave
When the S terminal selects function 72 and
takes effect, and P90.03=3, the macro
parameter is switched from P90.00 to P90.01,
and the master/slave switchover is automatically
performed.
4: Switch from the salve to the master
When the S terminal selects function 71 and
takes effect, and P90.03=4, the macro
parameter is switched from P90.00 to P90.01,
and the master/slave switchover is automatically
performed.
5: Switch to SVC1 control (open-loop vector
control 1)
When P90.03=5, P90.00 must be 2, while
P90.01 must be 1; alternatively, P90.00 must be
11, while P90.01 must be 12. Only control mode
can be switched, and the S terminal selects
function 62 and takes effect.
0–1
0: The brake is controlled by an external
controller.
1: The brake is controlled by the VFD.
0x00–0x11
Ones place: indicates whether to enable forward
torque for reverse-running start
0: Disable
(The reverse-running start direction complies
-330-
Function parameter list
Default
Modify
0
0x00