Goodrive350-19 series VFD for crane
Function
Name
code
Enabling
P08.37
energy-consumpti
on braking
Energy-
consumption
P08.38
braking threshold
voltage
Cooling-fan
P08.39
running mode
P08.40
PWM selection
Description
Output frequency
Set
frequency
Y,
RO1, RO2
Setting range:
0.00Hz–P00.03
frequency)
0x00–0x11
Ones place:
0: Disable
1: Enable
Tens place:
0: Disable braking short-circuit protection
1: Enable braking short-circuit protection
Braking short-circuit protection is disabled for
22kW and lower VFD models by default.
The function code is used to set the starting bus
voltage of energy consumption braking. Adjust
this value properly to achieve effective braking
for the load. The default value varies depending
on the voltage class.
Setting range: 200.0–2000.0V
0: The fan runs with the VFD; the fan stops 1
minute after the VFD stops.
1: Permanent running after power-on
2: Run mode 2
0x0000–0x1121
Ones place: PWM mode selection
0: PWM mode 1, 3PH modulation and 2PH
modulation
1: PWM mode 2, 3PH modulation
Tens place: PWM low-speed carrier frequency
limit
-261-
Detection amplitude
Time t
Time t
(Max. output
Function parameter list
Default
Modify
○
0x01
For 220V:
380.0V
For 380V:
○
700.0V
For 660V:
1120.0V
○
0
◎
0x1101