Goodrive350-19 series VFD for crane
DOWN (11), you can increase/decrease the frequency quickly by setting P08.45 (UP terminal
frequency incremental change rate) and P08.46 (DOWN terminal frequency decremental change
rate).
UP terminal
function selection=10
DOWN terminal
function selection=11
Related parameter list:
Function
code
P00.03
Max. output frequency
Upper limit of running
P00.04
Lower limit of running
P00.05
Setting channel of A
P00.06
frequency command
Setting channel of B
P00.07
frequency command
F
Sx
Sy
Name
frequency
frequency
UP terminal frequency incremental integral speed P08.45
DOWN terminal frequency decremental integral speed P08.46
Description
P00.04–400.00Hz
P00.05–P00.03 (Max. output frequency)
0.00Hz–P00.04
0: Keypad
1: AI1
2: AI2
3: AI3
4: High-speed pulse HDIA
5: Simple PLC program
6: Multi-step speed running
7: PID control
8: Modbus communication
9: Profibus/CANopen/DeviceNet
communication
10: Ethernet communication
11: High-speed pulse HDIB
12: Pulse train AB
13: EtherCAT/Profinet communication
14: Programmable expansion card
15: Multi-step speed run
-169-
Basic operation guidelines
T
UP terminal state
T
DOWN terminal state
T
Default
50.00Hz
50.00Hz
0.00Hz
0
15