Goodrive350-19 series VFD for crane
Function
code
Setting channel of A
P00.06
frequency command
Setting channel of B
P00.07
frequency command
P00.11
P00.12
P01.15
P03.25
P05.03
P05.04
P05.24
P05.28
P06.03
P06.04
Enabling brake-oriented
P90.04
Forward brake release
P90.14
Reverse brake release
P90.15
Forward brake release
P90.16
Reverse brake release
P90.17
Forward brake closing
P90.18
Reverse brake closing
P90.19
Table 5-3 Parameter settings for the closed-loop vector controlled winching application macro (using
Function
code
P00.00
Speed control mode
P00.01
Channel of running
Name
commands
ACC time 1
DEC time 1
Stop speed
Pre-exciting time
Function of S3
Function of S4
AI1 lower limit
AI1 input filter time
RO1 output
RO2 output
logic
torque
torque
frequency
frequency
frequency
frequency
analog reference -10V–10V)
Name
Setting
1
0
10.0s
5.0s
0.20 Hz
0.000
64
5
0.00V–P05.26. Adjust the value
0.20V
according to the actual situation.
0.100s
49
5
1
The brake is controlled by the VFD.
Corresponding to the motor rated
50.0%
Corresponding to the motor rated
50.0%
1.00Hz
1.00Hz
1.00Hz
1.00Hz
Setting
3
3: Closed-loop vector control mode
1
-63-
Commissioning guidelines
Remarks
AI1
Keypad
Disable pre-exciting.
Upward position limit
Fault reset
0.000s–10.000s
Brake output
VFD in fault
torque
torque
Remarks
Terminal
Need help?
Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?
Questions and answers