Goodrive350-19 series VFD for crane
Function
Name
code
Overmodulation
P08.41
selection
P08.42
Reserved
P08.43
Reserved
UP/DOWN
P08.44
terminal control
setting
Description
0: Low-speed carrier frequency limit mode 1
1: Low-speed carrier frequency limit mode 2
2: No limit on low-speed carrier frequency
Hundreds place: Deadzone compensation
method
0: Compensation method 1
1: Compensation method 2
Thousands place: PWM loading mode selection
0: Interruptive loading
1: Normal loading
0x00–0x1111
Ones place:
0: Disable
1: Enable
Tens place
0: Mild overmodulation
1: Deepened overmodulation
Hundreds: Carrier frequency limit
0:Yes
1:No
Thousands: Output voltage compensation
0: No
1: Yes
000–1223
0.01–10.00
0x000–0x221
Ones place: Frequency setting selection
0: The setting made through UP/DOWN is valid.
1: The setting made through UP/DOWN is
invalid.
Tens place: Frequency control selection
0: Valid only when P00.06=0 or P00.07=0
1: Valid for all frequency setting methods
2: Invalid for multi-step speed running when
multi-step speed running has the priority
Hundreds place: Action selection for stop
0: Setting is valid.
1: Valid during running, cleared after stop
-262-
Function parameter list
Default
Modify
◎
0x0001
○
0x0003
○
0.10s
○
0x000