Goodrive350-19 series VFD for crane
Function
Name
code
reference
Torque current
P17.34
reference
AC incoming
P17.35
current
P17.36
Output torque
Motor overload
P17.37
count value
Process PID
P17.38
output
Function codes in
P17.39
parameter
download error
Motor control
P17.40
mode
Electromotive
P17.41
torque upper limit
Braking torque
P17.42
upper limit
P17.43
Forward rotation
Description
under the vector control mode.
Range: -3000.0–3000.0A
Displays the torque current reference value
under the vector control mode.
Range: -3000.0–3000.0A
Displays the valid value of incoming current on
AC side.
Range: 0.0–5000.0A
Displays the output torque value. During forward
running, the positive value is the motoring state
while the negative value is generating state.
During reverse running, the positive value is the
generating state while the negative value is the
motoring state.
Range: -3000.0Nm–3000.0Nm
0–65535
-100.0%–100.0%
0.00–99.00
Ones place: Control mode
0: Vector 0
1: Vector 1
2: Space voltage vector control
3: Closed-loop vector control
Tens place: Control status
0: Speed control
1: Torque control
2: Position control
0: Motor 1
1: Motor 2
0.0%–300.0% (of the motor rated current)
0.0%–300.0% (of the motor rated current)
0.00–P00.03
-290-
Function parameter list
Default
Modify
0.0A
0.0A
0.0Nm
0
0.00%
0.00
0x2
180.0%
180.0%
50.00Hz