5.3.2 Commissioning procedure

1. Check the wiring and ensure the wiring is proper.
2. Set P00.18=1 to restore to default settings.
3. Set motor nameplate parameters in P02.
4. Set P90.00=3 to select the horizontal moving application macro.
5. Perform low-speed trial run.

5.3.3 Macro parameters (P90.00=3)

Function code
P00.01
P00.03
Max. output frequency
P00.04
P00.06
P00.11
P00.12
P01.01
P01.15
P05.03
P05.04
P06.03
P06.04
P10.04
P10.06
P10.08
P10.10
P11.05
P11.26
Enabling special functions
P25.01
P25.02
P25.03
P25.04
P25.10
Name
Channel of running
commands
Upper limit of running
frequency
Setting channel of A
frequency command
ACC time 1
DEC time 1
Starting frequency of
direct start
Stop speed
Function of S3
Function of S4
RO1 output
RO2 output
Multi-step speed 1
Multi-step speed 2
Multi-step speed 3
Multi-step speed 4
Current limit mode
Function of S5
Function of S6
Function of S7
Function of S8
Expansion card input
terminal polarity
Setting
1
100.00Hz
60.00Hz
6
Multi-step speed running
5.0s
4.0s
2.00Hz
1.00 Hz
0
7
5
1
8.0%
Corresponding to the max. frequency
18.0%
Corresponding to the max. frequency
32.0%
Corresponding to the max. frequency
50.0%
Corresponding to the max. frequency
Enable software and hardware
0x11
1
16
17
18
6
0x08
-47-
Commissioning guidelines
Remarks
Terminal
No function
Fault reset
VFD in fault
Running
current limit.
Multi-step speed 1
Multi-step speed 2
Multi-step speed 3
Coast to stop
Terminal polarity