Goodrive350-19 series VFD for crane
When selecting the customized V/F curve function, you can specify the setting channels and
acceleration/deceleration time of voltage and frequency respectively, which form a real-time V/F
curve in combination manner.
Note: This type of V/F curve separation can be applied in various variable-frequency power
sources. However, exercise caution when setting parameters as improper settings may cause
equipment damage.
Function
code
P00.00
Speed control mode
Max. output
P00.03
frequency
Upper limit of running
P00.04
frequency
P00.05
Lower limit of running 0.00Hz–P00.04
Name
0: Sensorless vector control (SVC) mode 0
1: Sensorless vector control (SVC) mode 1
2: Space voltage vector control mode
3: Closed-loop vector control mode
Note: Before using a vector control mode (0, 1, or
3), enable the VFD to perform motor parameter
autotuning first.
P00.04–400.00Hz
P00.05–P00.03
Description
-147-
Basic operation guidelines
Default
2
50.00Hz
50.00Hz
0.00Hz