Goodrive350-19 series VFD for crane
Function
Name
code
AVR function
P00.16
selection
Function
P00.18
parameter restore
P01 group––Start and stop control
Function
Name
code
P01.00
Start mode
Starting frequency
P01.01
of direct start
Starting frequency
P01.02
hold time
Description
5: Partial parameter static autotuning 2 (valid
only for AMs)
0: Disable
1: Valid during the whole procedure
The auto-adjusting function of the VFD can
eliminate the impact on the output voltage of the
VFD because of the bus voltage fluctuation.
Setting range of P00.18: 0–6
0: No operation
1: Restore default values
2: Clear fault records
3: Lock keypad parameters
4–6: Reserved
Note: After the selected operation is
performed, the function code is
automatically restored to 0. Restoring the
default values may delete the user password.
Exercise caution when using this function.
Description
0: Direct start
1: Start after DC braking
2: Speed tracking restart 1
3: Speed tracking restart 2
Note: It can be modified only when
indicating special functions are enabled.
The function code indicates the initial frequency
during VFD start. See
frequency hold time) for detailed information.
Setting range: 0.00–50.00Hz
Output frequency
fmax
F1 set by P01.01
T1 set by P01.02
f1
t1
-210-
P11.26
P01.02
(Starting
T
Function parameter list
Default
Modify
1
0
Default
Modify
0
is 1
0.50Hz
0.0s
○
◎
◎
◎
◎
Need help?
Do you have a question about the Goodrive350-19 Series and is the answer not in the manual?
Questions and answers