Goodrive350-19 series VFD for crane
Function
code
P12.00
Type of motor 2
P12.01
Rated power of AM 2
P12.02
Rated frequency of AM 2 0.01Hz–P00.03 (Max. output frequency)
P12.03
Rated speed of AM 2
P12.04
Rated voltage of AM 2 0–1200V
P12.05
Rated current of AM 2 0.8–6000.0A
P12.06
Stator resistance of AM 2 0.001–65.535Ω
P12.07
Rotor resistance of AM 2 0.001–65.535Ω
Leakage inductance of
P12.08
Mutual inductance of AM
P12.09
P12.10
No-load current of AM 2 0.1–6553.5A
P12.15
Rated power of SM 2
P12.16
Rated frequency of SM 2 0.01Hz–P00.03 (Max. output frequency)
Number of pole pairs of
P12.17
P12.18
Rated voltage of SM 2 0–1200V
P12.19
Rated current of SM 2 0.8–6000.0A
Name
4: EtherCAT/Profinet communication
5: 216 communication
Tens place: indicates whether to enable
switchover during running
0: Disable
1: Enable
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0.1–3000.0kW
1–36000rpm
0.1–6553.5mH
AM 2
0.1–6553.5mH
2
0.1–3000.0kW
1–50
SM 2
Description
-162-
Basic operation guidelines
Default
0
Model
depended
50.00Hz
Model
depended
Model
depended
Model
depended
Model
depended
Model
depended
Model
depended
Model
depended
Model
depended
Model
depended
50.00Hz
2
Model
depended
Model
depended