P26 Group--I/O Card Output Functions - INVT Goodrive350-19 Series Operation Manual

Hide thumbs Also See for Goodrive350-19 Series:
Table of Contents

Advertisement

Goodrive350-19 series VFD for crane
Function
Name
code
AI3 input filter
P25.34
time
AI3 input signal
P25.41
type
S-terminal power
signal selection
P25.42
(S terminal on
I/O card 2)
P26 group––I/O card output functions
Function
Name
code
P26.02
Y2 output
P26.04
RO3 output
P26.05
RO4 output
P26.12
Expansion card 0x0000–0x7FF
Description
See the descriptions of each application section
for details.
The following figure illustrates the cases of
several settings:
Corresponding
setting
100%
0
AI3/AI4
-100%
Input filter time: to adjust the sensitivity of analog
input. Increasing the value properly can
enhance analog input anti-interference but may
reduce the sensitivity of analog input.
Note: AI3 can support 0–10V/0–20mA input.
When AI3 selects 0–20mA input, the
corresponding voltage of 20mA is 10V.
P25.30
setting range:
setting range: -300.0% –300.0%
P25.31
P25.32
setting range: P25.30–10.00V
setting range: -300.0% –300.0%
P25.33
P25.34
setting range: 0.000s–10.000s
Range: 0–1
0: Voltage
1: Current
0–1
0: DC (24–48V DC)
1: AC (24–48V AC)
Description
-318-
AI
10V
20mA
0.00V–P25.32
Function parameter list
Default
Modify
0.030s
0
0
Default
Modify
0
0
0
0x000