Goodrive350-19 series VFD for crane
Function
Name
code
Restart selection
P90.38
during braking
Wait time for
P90.39
restart
Braking method in
P90.40
open-loop vector
control
Description
P90.38
setting range: 0–1
0: No restart during braking
P 90.39
Wait time of
Output
frequency
Running
FWD
command
During the stop, if the brake closing command
has been output, the system does not accept
any new startup commands, and it can be
restarted with a wait time of
brake is closed and VFD stops.
1: Restart allowed during braking
Output
frequency
Running
FWD
command
Though the brake closing command has been
output during stop, the VFD accepts a new start
command.
P90.39
setting range: 0.0–10.0s
0–3
0: Common mode
1: Torque mode with limit 1
The limit is specified by P90.41.
2: Torque/speed switchover mode 1 (boost with
braking)
It is used when P90.04=1 since the brake is
involved. When the brake is opened, the speed
mode is automatically used.
3: Torque/speed switchover mode 2 (horizontal
moving)
Since the brake is not involved, the
torque/speed switchover is set through P90.44.
The set frequency must be greater than P90.44.
-338-
restart
REV
P90.39
after the
REV
Function parameter list
Default
Modify
0
0.5s
0