Goodrive350-19 series VFD for crane
Function
Name
code
Torque of upward
P93.32
loose rope
autotuning
Torque of
P93.33
downward loose
rope autotuning
Description
Output
frequency
P93.31
P93.26
P93.28
Target
frequency
Output
Loose rope
torque
protection fault
P93.25
Normal
SLE fault
VFD status
1: Mode 2. The VFD outputs the loose rope
protection alarm (A-SL), changes the direction,
and runs upward at the frequency specified by
P93.31, and the VFD runs downward only when
the time specified by
loose rope status disappears.
P93.30
setting range: 0–20.00s
P93.31
setting range: 1.00Hz–10.00Hz
Note:
P93.30
must be greater than the sum of
the time taken to decelerate from
and the time taken to accelerate from 0Hz to
P93.31.
The autotuning procedure is as follows:
Step 1 Put the hook on the ground and loosen
the rope.
Step 2 Set P93.19=1 (or
running).
Step 3 Push the operating lever to step-2 speed
(higher than 10Hz), which is held at least 1s in
the loose rope state after the frequency is stable
(to autotune stable frequency torque).
Step 4 Stop the device and check the autotuning
result. If
P93.32
(or
P93.33
-369-
Output
frequency
Time t
P93.26
P93.28
Target
frequency
Non loose rope
Output torque
P93.25
Normal
VFD status
P93.30
is reached or the
P93.26
P93.19
for downward
for downward
Function parameter list
Default
Time t
status
to 0Hz
0.0%
0.0%
Modify