Goodrive350-19 series VFD for crane
P10.00(simple PLC mode)
Stop after running
0
once
1
Keep running in the
final value after
running once
2
Cyclic running
PLC mode
Digital output 16
Simple PLC state completed
Digital output 17
Simple PLC cycle completed
Related parameter list:
Function
code
P05.01–
Digital input function selection
P05.06
P06.01–
Digital output function
P06.04
P10.00
Simple PLC mode
Simple PLC memory
P10.01
P10.02
Multi-step speed 0
P10.03
Running time of step 0
P10.04
Multi-step speed 1
P10.05
Running time of step 1
P10.06
Multi-step speed 2
P10.07
Running time of step 2
P10.08
Multi-step speed 3
P10.09
Running time of step 3
P10.10
Multi-step speed 4
P10.11
Running time of step 4
P10.01 (simple PLC memory selection)
Power cut during
running
Setup of running
parameters of each
PLC stage
Normal running
Name
selection
selection
0
No memory
after power off
1
Memory after
power off
P10.36
(PLC restart mode)
Description
23: Simple PLC stop reset
24: Pause simple PLC
25: Pause PID control
16: Simple PLC stage reached
17: Simple PLC cycle reached
0: Stop after running once
1: Keep running with the final value after
running once
2: Cyclic running
0: No power-failure memory
1: With power-failure memory
-100.0–100.0%
0.0–6553.5s (min)
-100.0–100.0%
0.0–6553.5s (min)
-100.0–100.0%
0.0–6553.5s (min)
-100.0–100.0%
0.0–6553.5s (min)
-100.0–100.0%
0.0–6553.5s (min)
-188-
Basic operation guidelines
Restart running
0
after the first
section
0
1
Continue running at
1
the frequency when
interruption occurred
Terminal function 23
Simple PLC stop reset
Set frequency
P17.00
Default
0
0
0.0%
0.0s
0.0%
0.0s
0.0%
0.0s
0.0%
0.0s
0.0%
0.0s