Siemens SINUMERIK 840D sl Series Diagnostics Manual page 281

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Remedy:
Press RESET key.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
16920
Channel %1 action %2<ALNX> is already active
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
An identical action is still active.
Reactions:
- Alarm display.
Remedy:
Wait until the first procedure is terminated or abort with Reset and repeat the operation.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
16921
Channel %1 mode group %2 machine data: channel/mode group assignment not
allowed or assigned twice
Parameters:
%1 = Channel number
%2 = Mode group number
Definitions:
On powering up, an illegal channel/mode group assignment was detected.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Check machine data
ASSIGN_CHAN_TO_MODE_GROUP.
Program Con-
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
tinuation:
16922
Channel %1 subprograms: action %2<ALNX> maximum nesting depth exceeded
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
Various actions can cause the current procedure to be interrupted. Depending on the
action, asynchronous subroutines are activated. These asynchronous subroutines can be
interrupted in the same manner as user programs. Unlimited nesting depth is not possible
for asynchronous subroutines due to memory limitations.
Example: An interrupt interrupts the current program processing. Other interrupts with
higher priorities interrupt processing of the previously activated asynchronous subrou-
tines.
Possible actions are: DryRunOn/Off, DecodeSingleBlockOn, delete distance-to-go, inter-
rupts .....
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Do not trigger the event on this block.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
16923
Channel %1 program control: action %2<ALNX> not allowed in the current state
Parameters:
%1 = Channel number
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-281

Advertisement

Table of Contents
loading

Table of Contents