Siemens SINUMERIK 840D sl Series Diagnostics Manual page 164

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12552
Channel %1 block %2 tool/magazine OEM parameter not defined. Option not set.
Option not set.
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed $TC_... Cx system variable is not known in the control.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
• Correct the name used (writing error)
• $TC_DPCx, $TC_TPCx, $TC_MOPCx, $TC_MAPCx, $TC_MPPCx, $TC_DPCSx,
$TC_TPCSx, $TC_MOPCSx, $TC_MAPCSx, $TC_MPPCSx; with x=1,...10
• These are the OEM parameters of the tools magazines, The corresponding machine
data value is set to < 10, or the option 'TM OEM parameters' has not been set.
• Use correct parameter number, or - if the name cannot be changed - set machine data
correction (see $MN_MM_NUM_CC_TOA_PARAM, ...
$MN_MM_NUM_CCS_TOA_PARAM, ...). )
• Check the option (machine data are only effective when the option is enabled).
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12553
Channel %1 block %2 name %3 Function is not active
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The NC function belonging to this language command is not active.
But the name of the language command is known. Each programming
of this language command is rejected with this alarm.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Press key NC Stop and select "Correction set" function by pressing softkey PROGRAM
CORRECT. The correction indicator is set to the incorrect block.
• Correct the name used (typing error)
• Activate the NC function.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12555
Channel %1 block %2 function not available (identification %3)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Fine ID
Definitions:
The identifier has not been defined for this system
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Press the NC stop key and select the "Compensation block" function by pressing the
"Program correct" softkey. The correction indicator will position in the incorrect block.
• Correct the name used (write error)
2-164
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading