Siemens SINUMERIK 840D sl Series Diagnostics Manual page 297

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
%2 = Block number, label
Definitions:
The maximum memory space of 8 KB available for a symbol has been exceeded.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Reduce array dimensions.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
17070
Channel %1 block %2 data is write-protected
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An attempt was made to write to a write-protected variable (e.g. a system variable).
Safety Integrated: Safety system variables can only be modified from the safety SPL pro-
gram.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
17080
Channel %1 block %2 %3 value below lower limit
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = MD
Definitions:
An attempt was made to write a machine data with a value that is smaller than the defined
lower limit.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Determine the input limits of
the machine data and assign a value within these limits.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
17090
Channel %1 block %2 %3 value exceeds upper limit
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = MD
Definitions:
An attempt was made to write a machine data with a value that is greater than the defined
upper limit.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Determine the input limits of
the machine data and assign a value within these limits.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
17095
Channel %1 block %2 invalid value
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-297