Definitions: The Alarm Is Triggerd By The Following Cycles: Cycle971; Remedy: Check Parameter; Parameters: %1 = Channel Number - Siemens SINUMERIK 840D sl Series Diagnostics Manual

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE118.
4th parameter for CYCLE118 is larger than 10.
Remedy:
Reduce the 4th parameter (PAR4) of CYCLE118.
61363
Channel %1 Block %2: Max. no. of value lines for recording exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Maximum number of value lines exceeded.
Alarm triggerd by following cycle: CYCLE105.
Remedy:
Reduce the number of value lines.
Check parameter _PROTFORM[4].
61364
Channel %1 block %2: Check distance from measuring point 1 to measuring point2
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE998.
Parameter _ID is <= 0.
Remedy:
Check parameter _ID.
61365
Channel %1 block %2: Check circular feed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE979.
Parameter _RF is <= 0.
Remedy:
Check parameter _RF.
61366
Channel %1 block %2: Direction of rotation for tool measurement with rotating
spindle not specified in _CM[5]
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE971.
Permissible values for data field _CM[5] in GUD6 block are 3 (corresponds to M3) or 4
(corresponds to M4).
Remedy:
Check parameter _CM[5] in GUD6.
61367
Channel %1 block %2: Parameters _SETV[0...3] or _SETV[...7] are identical
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE961.
Remedy:
Specify different positions for the relevant points of _SETV[0...7] .
61368
Channel %1 block %2: Straights through parameter _SETV[0...3] or _SETV[4...7]do
not intersect
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE961.
Remedy:
Specify different positions for the relevant points of _SETV[0...7] .
2-488
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved