%2 = Block number, label
Definitions:
With involute interpolation, the end point of the involute must be outside the basic circle.
The programmed center point / radius or end point must be adapted accordingly.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14037
Channel %1 block %2 involute: radius invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, the programmed radius of the basic circle must be greater
than zero.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14038
Channel %1 block %2 involute not definable: end point error
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed end point does not lie on the involute defined by the start point, radius
and center point of the basic circle. The deviation of the effective end radius from the pro-
grammed value is greater than the permissible value specified in MD
INVOLUTE_RADIUS_DELTA.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14039
Channel %1 block %2 involute: end point programmed several times
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, either the end point with the geometry axis identifiers or the
angle of rotation with AR=value can be programmed. Simultaneous programming of end
point and angle of rotation in one block is not allowed, since the end point can thus not be
defined exactly.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14040
Channel %1 block %2 error in end point of circle
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms