Overview of Alarms
14755
Channel %1 block %2 motion synchronous actions without traverse motion
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed motion synchronous action and the function "Several feeds" require a
traversing motion or the value of the traversing motion is 0.
This alarm is no longer used after P3.2.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14756
Channel %1 block %2 motion synchronous action and wrong value
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Value of the synchronous action or the function "Several feeds" is not allowed.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program. Check whether a negative value was entered for a synchronous
action.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14757
Channel %1 block %2 motion synchronous action and wrong type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Programmed combination between action and type of motion synchronous action is not
allowed.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14758
Channel %1 block %2 programmed value not available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The synchronous variables $AA_LOAD, $AA_TORQUE, $AA_POWER and $AA_CURR
are available only for the 611D drive. They are activated by the machine data MDC 36730
DRIVE_SIGNAL_TRACKING. The system variable $VA_IS: Safe Actual Position is avail-
able only if the machine data $MA_SAFE_FUNCTION_ENABLE has been set and the
option $ON_NUM_SAFE_AXES has been set to a sufficient size.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify program or machine data.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation: