Siemens SINUMERIK 840D sl Series Diagnostics Manual page 243

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
For the second reason, please check whether the system has correctly not activated the
channel mentioned.
If the channel has been activated, operation may be continued after another NCK
RESET/POWER ON without further measures, i.e. reloading the file is not required. If the
channel has not been activated, make sure that the channel inactivated by mistake is re-
activated.
If the settings of the channel activation are part of the file to be loaded (e.g. archive file),
the file must either be modified with the relevant program or the file has to be created
once more in the same system with the correct channel number.
Similar alarms: 15020, 15021.
Program Con-
Switch control OFF - ON.
tinuation:
15030
Channel %1 block %2 different measurement system settings
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The INCH or METRIC instruction describes the system of measurement in which the data
blocks have been read from the control. In order to prevent the incorrect interpretation of
data intended for a particular system of measurement, a data block is only accepted if the
above instruction matches the active system of measurement.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Change the system of measurement or load a data block which matches the system of
measurement.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15100
Channel %1 block %2 REORG abort caused by log file overflow
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In order to synchronize the preprocessing run and the main run with REORG, the control
accesses modification data which are maintained in a logfile. The alarm indicates that no
more capacity is available in the logfile for the specified block in the channel.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. No remedial measures are
available for the further execution of the current NC program, however:
1. Reduce log file size requirement by:
Reducing the distance between the preprocessing and the main run via appropriate pre-
processing stops STOPRE.
2. The logfile should be increased in size by means of the channel-specific data:
Modify MD 28000: MM_REORG_LOG_FILE_MEM and
Modify MD 28010: MM_REORG_LUD_MODULES
Attention!
A change in these machine data also causes a reallocation of the NCK user memory and
the standard machine data are then loaded. Unless a data save is performed, there will
be a LOSS OF DATA!'
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-243