Overview of Alarms
101006
Password has been deleted !
Definitions:
The password was deleted via the softkey "Delete password".
Remedy:
Enter password.
101007
Password has not been set !
Definitions:
To delete the password, a higher access authorization is required (at least user).
Remedy:
Set the password with a higher access level.
101008
Actual access level: %1
Parameters:
%1 = Access-level system, manufacturer, service or user.
Definitions:
When selecting the alarm image, the current access level is displayed: system, manufac-
turer, service or user or keyswitch positions 3/2/1/0.
Remedy:
--
101013
Input error - see Help key (i)
Definitions:
PLC status A syntax error occurred while entering a value in the PLC status.
The input syntax is explained in a help image.
Remedy:
--
101014
Error on reading PLC_data !
Definitions:
--
Remedy:
--
101015
Error on writing PLC_data !
Definitions:
--
Remedy:
--
101016
Error: Operand address greater than 65535 !!
Definitions:
The value range of the operand address was exceeded.
Remedy:
Use a smaller value range for the operand address.
101017
No PLC input forms found !
Definitions:
There are no *.plc input screen forms in the target system.
Remedy:
--
101018
Read-in possible only in active PLC status !
Definitions:
The current PLC status mode is not active, e.g. if the softkey "Change" was pressed.
Remedy:
Switch the PLC status to active.
101019
Not possible to initialize the HMI internal PLC status!
Definitions:
--
Remedy:
--
101020
Not possible to backup the HMI internal PLC status!
Definitions:
--
Remedy:
--
101100
No access rights !
Definitions:
The access level set is too low to open the selected window.
Remedy:
Enter a higher password.