Siemens SINUMERIK 840D sl Series Diagnostics Manual page 490

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE977
For the measuring variant Measure web/shaft, the position path in the plane was limited
by the software limit position. The probe switched in the following infeed along the infeed
axis.
Remedy:
Check programmed position regarding software end position.
61403
Channel %1 block %2: Internal cycle error during frame calculation.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Call the SIEMENS hotline
61404
Channel %1 block %2: Internal cycle error during tool offset.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check the dependent tool specifications.
61405
Channel %1 block %2: tool environment does not exist in _TENV
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Correct the names or create this environment.
61406
Channel %1 block %2: check DL number in _DLNUM
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check the number of additive offset and setup offset.
Check parameter _DLNUM.
61407
Channel %1 block %2: check 7th digit and higher of _KNUM
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The 6th position of _KNUM includes invalid values.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check the number of additive offset and setup offset.
Check parameter _KNUM.
61408
Channel %1 block %2: total offsets not present
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Set MD 18080, Bit 8=1
61409
Channel %1 block %2: set up offsets not present
Parameters:
%1 = Channel number
%2 = Block number, label channel number
2-490
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents