Siemens SINUMERIK 840D sl Series Diagnostics Manual page 83

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Remedy:
Please inform the authorized personnel/service department. Do not use rapid interrupt
inputs or contact the machine manufacturer with a view to retrofitting this option!
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
8010
Option 'activation of more than %1 axes' not set
Parameters:
%1 = Number of axes
Definitions:
More machine axes have been defined through the channel-specific MD 20070
AXCONF_MACHAX_USED than are allowed in the system.
Reactions:
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. The sum of all axes that
have been configured through the channel-specific MD 20070
AXCONF_MACHAX_USED, must not exceed the maximum number of axes (dependent
on configuration -> option, basic version: 4 axes).
Program Con-
Switch control OFF - ON.
tinuation:
8020
Option 'activation of more than %1 channels' not set
Parameters:
%1 = Number of channels
Definitions:
A 2nd channel has been indicated but the corresponding option does not exist.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
In the system-specific MD 10010 ASSIGN_CHAN_TO_MODE_GROUP, reduce the num-
ber of channels to 1 or retrofit the option for a 2nd channel.
Program Con-
Switch control OFF - ON.
tinuation:
8021
Option 'activation of more than %1 mode groups' not set
Parameters:
%1 = Number of mode groups
Definitions:
The option for the number of mode groups is not compatible with the activated mode
group.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Add option for more mode groups. Activate fewer mode groups.
Program Con-
Switch control OFF - ON.
tinuation:
8022
Option 'activation of more than %1KB SRAM' not set
Parameters:
%1 = Memory size
Definitions:
The option for memory extension does not correspond to the active SRAM.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-83

Advertisement

Table of Contents
loading

Table of Contents