Siemens SINUMERIK 840D sl Series Diagnostics Manual page 614

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
Remedy:
Not necessary. As soon as all channels viewed for time determination are in Reset again,
this message will be cancelled automatically.
Program Con-
Internal
tinuation:
129904
%1: Current NCK Version %2 is too low for time measurement. Version 500000 or
higher will be required.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
%2 = Current NCU version
Definitions:
The version of the specified NCU is too old (< 500000).
Remedy:
Upgrade or replace the relevant NCU for the required software version in order to use the
time determination.
129905
%1: Unable to determine the NCK version for time measurement.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
Definitions:
The version of the specified NCU could not be determined.
Remedy:
Connect to the NCU and restart the PCU if required.
129906
%1: Unable to determine the number of channels.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
Definitions:
The number of channels of the specified NCU could not be determined.
Remedy:
Connect to the NCU and restart the PCU if required.
129907
%1:The max. number of channels could not be determined.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
Definitions:
The maximum number of channels of the specified NCU could not be determined.
Remedy:
Connect to the NCU and restart the PCU if required.
129908
%1: Unable to determine active channels.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
Definitions:
The active channels of the specified NCU could not be determined.
Remedy:
Connect to the NCU and restart the PCU if required.
129909
%1: Unable to determine the name of channel %2.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
%2 = Channel number
Definitions:
The channel name of the specified NCU could not be determined.
Remedy:
Connect to the NCU and restart the PCU if required.
129910
%1: Unable to determine general machine data.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
Definitions:
The general machine data of the specified NCU could not be determined.
Remedy:
Connect to the NCU and restart the PCU if required.
129911
%1: Unable to determine machine data $MN_MM_PROTOC_NUM_FILES[1,10].
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
Definitions:
Machine data MN_MM_PROTOC_NUM_FILES[1,10] of the specified NCU could not be
determined.
Remedy:
Connect to the NCU and restart the PCU if required.
2-614
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

Table of Contents