Remedy:
Please inform the authorized personnel/service department.
1. Modify machine data: Select the same identifiers for geometry and channel axes in all
channels. Example: The geometry axes are called X, Y, Z in all channels. They can then
also be programmed directly in preprocessed channels.
2. Do not program the axis directly in the cycle but define it as a parameter of the axis
type. Example: Cycle definition:
PROC DRILL(AXIS DRILLAXIS) G1 AX[DRILLAXIS]=10 F1000 M17
Call from the main program:
DRILL(Z)
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
12660
Channel %1 block %2 motion synchronous action: variable %3 reserved formotion
synchronous actions and technology cycles
Parameters:
%1 = Channel number
%2 = Block number
%3 = Variable name
Definitions:
The displayed variable may only be used in motion synchronous actions or in technology
cycles. For example, '$R1' may only be used in motion synchronous actions. In standard
part programs R parameters are programmed with R1.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
12661
Channel %1 block %2 technology cycle %3: no further subprogram call possible
Parameters:
%1 = Channel number
%2 = Block number
%3 = Name of the technology cycle call
Definitions:
In a technology cycle it is not possible to call a subroutine or another technology cycle.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
12700
Channel %1 block %2 contour definition programming not allowed as modal sub-
programis active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the external language mode, a block is programmed with contour definition and a
modal cycle is active at the same time. Because of unclear address assignment (e.g. R =
radius for contour definition or return plane for drilling cycle) contour definition program-
ming must not be used when a modal cycle is active.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition