61188
Channel %1 block %2: No axis name agreed for 1st rotary axis -> Start-up check
CYCLE800
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No axis name was specified for the 1st rotary axis. Alarm triggered by following cycles:
CYCLE800.
Remedy:
Check installation and start-up of the swivel cycle CYCLE800.
61189
Channel %1 block %2: invalid rotary axis positions
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE800.
Remedy:
Swivel in JOG, swivel mode direct, check position of rotary axes or start-up of swivel cycle
CYCLE800 rotary axes, check area of angles.
61190
Channel %1 block %2: unable to retract in tool direction --> error code: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE800.
Note on 61190
61190 Retraction in tool direction not possible --> error code: %4
Error code %4 = abcd
a=0xxx -> Parameter CYCLE800 _FR incorrect or retraction variant in start-up
CYCLE800 not created.
a=1xxx -> No applicats available $P_AXN3
a=2xxx -> Maximum retraction path incorrect, see GUD _TC_P[8]
a=3xxx -> Incremental retraction path incorrect, see GUD _TC_P[8]
b=Input parameter _FR*100
cd=Start-up parameter $P_TCARR37[] (7th,8th decimal place)
see table Coding retraction modes.
Remedy:
Error code: %4
61191
Channel %1 block %2: 5 axis transformation not set up
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm is triggerd by the following cycles: CYCLE832.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
--
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61192
Channel %1 block %2: second 5 axis transformation not set up
Parameters:
%1 = Channel number
%2 = Block number, label
2-454