Siemens SINUMERIK 840D sl Series Diagnostics Manual page 81

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Set the machine data for
dividing up the VDI user interface of the compile cycles (DB 9) into input and output bytes
in accordance with the functions in the compile cycles. The maximum quantity of 400
bytes must not be exceeded. There are no restrictions concerning the division into input
and output bytes.
Program Con-
Switch control OFF - ON.
tinuation:
7200
Problem with externally linked compile cycle %1 %2
Parameters:
%1 = Description string
%2 = Additional information
Definitions:
Problem with loadable compile cycles
Example:
"Version_conflict_with_CCNCKInterface_Version"
Meaning: The interface version of the compile cycle is incompatible with the NCK ver-
sion.
"Loader_problem_from_dFixup"
Meaning: Unresolved references are left over after loading of all compile cycles, for exam-
ple as an ELD file is missing.
Reactions:
- Alarm display.
Remedy:
See function description of the compile cycle!
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
7201
Assertion error in %1 line %2
Parameters:
%1 = String (path with program name)
%2 = String (line number)
Definitions:
This alarm is purely a development alarm. It only occurs with externally linked compile
cycles.
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Alarm reaction delay is canceled.
Remedy:
Consultation with CC developer
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
7202
Missing option bit for %1: %2 <hex>
Parameters:
%1 = (string) name of the specific .elf file
%2 = (int) required option bit (hex)
Definitions:
Alarm for SIEMENS compile cycles. This alarm appears when the option bit required for a
SIEMENS compile cycle is not set.
Reactions:
- NC not ready.
- Channel not ready.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-81