08/2005
- Alarm display.
Remedy:
It is necessary to deactivate all links that are being used by the curve table to be deleted.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10941
Channel %1 block %2: Curve table %3: NC SRAM memory full, type %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
%4 = Object type
Definitions:
Insufficient free dynamic memory during curve table definition.
The object type parameter specifies for which curve table object
the memory will not suffice:
1: Number of curve tables too small (MD $MN_MM_NUM_CURVE_TABS)
2: Number of linear curve table segments too small (MD
$MN_MM_NUM_CURVE_SEG_LIN)
3: Number of polynomial curve table segments too small (MD
$MN_MM_NUM_CURVE_SEGMENTS)
4: Number of curve table polynomials too small (MD
$MN_MM_NUM_CURVE_POLYNOMS)
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Delete curve tables that are
no longer required, or reconfigure the disk space for the curve tables. The curve table def-
inition process now has to be repeated; see machine data:
MN_MM_NUM_CURVE_TABS, MD MN_MM_NUM_CURVE_SEGMENTS,
MN_MM_NUM_CURVE_SEG_LIN,
MN_MM_NUM_CURVE_POLYNOMS.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10942
Channel %1 block %2 curve table %3: illegal instruction during definition
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
Various illegal command sequences cause the output of this alarm during the definition of
the curve table. For example, it is impermissible to terminate definition of a curve table
with M30 before programming the CTABEND command.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Correct the part program and start it again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10943
Channel %1 block %2 curve table %3: direction reversal of lead value in the block
not allowed
Parameters:
%1 = Channel number
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-135