Remedy:
Check the operating steps to establish whether geometry axes really must be traversed,
otherwise switch over to the machine axes by activating the "WCS/MCS" key on the
machine control panel.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
20061
Channel %1 axis %2 cannot be traversed as orientation axis
Parameters:
%1 = Channel number
%2 = Axis name
Definitions:
The axis is not an orientation axis and can therefore not be traversed as an orientation
axis in JOG mode.
Reactions:
- Alarm display.
Remedy:
Register the axis as an orientation axis.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
20062
Channel %1 axis %2 already active
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
The displayed axis is already traversing as a machine axis. Therefore, it cannot be oper-
ated as a geometry axis.
Traversing of an axis can take place in JOG mode through 2 different interfaces.
1. as a geometry axis: via the channel-specific interface DB 21 - DB 28, DBX12.6 or
DBX12.7
2. as a machine axis: via the axis-specific interface DB 31 - DB 48 DBX8.6 or DBX8.7
With the standard machine control panel, it is not possible to operate an axis as machine
axis and geometry axis at the same time.
Reactions:
- Alarm display.
Remedy:
Do not start the geometry axis until the traversing motion as machine axis has been con-
cluded.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
20063
Channel %1 axis %2 orientation axes cannot be traversed without transformation
Parameters:
%1 = Channel number
%2 = Axis name
Definitions:
An attempt was made to move an orientation axis in JOG mode without an active orienta-
tion transformation.
Reactions:
- Alarm display.
Remedy:
Activate an orientation transformation.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
20065
Channel %1 master spindle not defined for geometry axes in JOG mode
Parameters:
%1 = Channel number
Definitions:
The displayed axis is to be traversed as geometry axis in JOG mode with rotary feed, but
no master spindle has been defined from which the actual speed could be derived.
Reactions:
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Remedy:
If the revolutional feed is also to be active in JOG mode, then a master spindle must be
declared via the channel-specific machine data 20090 SPIND_DEF_MASTER_SPIND. In
© Siemens AG, 2005. All rights reserved