Overview of Alarms
Parameters:
%1 = Channel number
Definitions:
It is not allowed to enter this data while the part program is being executed (e.g. setting
data for working area limitation or for dry run feedrate).
Reactions:
- Alarm display.
Remedy:
The data to be entered must be altered before starting the part program.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
4240
Runtime overflow for IPO cycle or position controller cycle, IP %1
Parameters:
%1 = Program location
Definitions:
The settings for the interpolation and position control cycle were modified before the last
power-up such that too little computing time is now available for the requisite cyclic task.
The alarm occurs immediately after power-up if too little runtime is available even when
the axes are stationary and the NC program has not started. However, task overflow can
occur only when computation-intensive NC functions are called during program execu-
tion.
Reactions:
- NC not ready.
- The NC switches to follow-up mode.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Alarm reaction delay is canceled.
Remedy:
Please inform the authorized personnel/service department. Take greater care when opti-
mizing the clock times NCK MD 10050 SYSCLOCK_CYCLE_TIME, MD 10060
POSCTRL_SYSCLOCK_TIME_RATIO and/or MD 10070
IPO_SYSCLOCK_TIME_RATIO.
The test should be performed with an NC program that represents the worst case. For
safety, a margin of 15 to 25% should be added to the times determined in this way.
Program Con-
Switch control OFF - ON.
tinuation:
4250
FastPlcCom functionality not available
Definitions:
This alarm indicates that the PLC provides the None FastPlcCom functionality during
start-up although this functionality is requested by the NCK.
Reactions:
- Alarm display.
Remedy:
Retrofit the PLC with the FastPlcCom functionality or deactivate the FastPlcCom function-
ality by means of NCK machine data.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
4252
PLCIO read error: %1
Parameters:
%1 = PLCIO error code
Definitions:
This alarm indicates that errors occured when reading the PLCIO with the FastPlcCom
functionality.
Reactions:
- Alarm display.
Remedy:
Check machine data MD 10394/10395 or check the PLC hardware configuration.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
4254
PLCIO write error: %1
2-50
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition