08/2005
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14082
Channel %1 block %2 label %3 program section not found
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Start or end label
Definitions:
The start point for repetition of the program part with CALL <program name> BLOCK
<start label> TO <end label> has not been found or the same program part repetition has
been called recursively.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Check the start and end labels for programming repetition in the user program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14085
Channel %1 block %2 instruction not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The instruction 'TML()' may only be used in the subprogram, which replaces the T com-
mand.
Reactions:
- Correction block is reorganized.
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14088
Channel %1 block %2 axis %3 doubtful position
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
An axis postion larger than 3.40e+38 increments has been programmed. This alarm can
be suppressed with bit 11 in $MN_SUPPRESS_ALARM_MASK.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14090
Channel %1 block %2 invalid D number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A value less than zero has been programmed under address D.
A set of parameters with 25 correction values has been automatically assigned to each
active tool. Each tool can have 9 sets of parameters (D1 - D9, initial setting is D1). When