Siemens SINUMERIK 840D sl Series Diagnostics Manual page 46

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
for channel synchronization in ISO2/3 mode or the machine data
$MN_EXTERN_CHAN_SYNC_M_NR_MAX is smaller than
$MN_EXTERN_CHAN_SYNC_M_NR_MIN.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Check machine data $MN_EXTERN_CHAN_SYNC_M_NR_MIN and
$MN_EXTERN_CHAN_SYNC_M_NR_MAX.
Program Con-
Switch control OFF - ON.
tinuation:
4180
Invalid M function number assigned to enable ASUP
Definitions:
An invalid M function number has been assigned for activation of ASUP. An illegal M
number has been assigned in machine data $MN_EXTERN_M_NO_SET_INT or
$MN_EXTERN_M_NO_DISABLE_INT for the configuration of the M number range for
activation/deactivation of the interrupt program.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Check machine data $MN_EXTERN_ M_NO_SET_INT and
$MN_EXTERN_M_NO_DISABLE_INT.
Program Con-
Switch control OFF - ON.
tinuation:
4181
Channel %1 invalid assignment of an M auxiliary function number
Parameters:
%1 = Channel number
Definitions:
In machine data $MC_AUXFU_ASSOC_M0_VALUE or
$MC_AUXFU_ASSOC_M1_VALUE, a number has been specified for the configuration of
a new predefined M function which is occupied by the system, and cannot be used for an
assignment. (M0 to M5, M17, M30, M40 to M45).
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Configure an M function in machine data $MC_AUXFU_ASSOC_M0_VALUE or
$MC_AUXFU_ASSOC_M1_VALUE which is not occupied by the system (M1 to M5, M17,
M30, M40 to M45).
Program Con-
Switch control OFF - ON.
tinuation:
4182
Channel %1 invalid M auxiliary function number in %2%3, MD reset
Parameters:
%1 = Channel number
%2 = MD identifier
%3 = If required, MD index
2-46
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005