Siemens SINUMERIK 840D sl Series Diagnostics Manual page 765

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Cause:
Communications with the DRIVE-CLiQ component specified by the fault value is not
possible.
One cause can be, e.g. that a DRIVE-CLiQ cable has been withdrawn.
Fault value (r0949, decimal):
Component ID.
Remedy:
- check the DRIVE-CLiQ connections.
- carry-out a POWER ON.
232899
<location>Encoder 2: Unknown fault
Reaction:
A_INFEED: OFF2 (DCBRAKE, NONE, OFF1, OFF3, STOP1, STOP2)
SERVO: ENCODER (DCBRAKE, NONE, OFF1, OFF2, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
A fault occurred on the sensor module for encoder 2 that cannot be interpreted by the
control unit firmware.
This can occur if the firmware on the sensor module for encoder 2 is more recent than the
firmware on the control unit.
Fault value (r0949, decimal):
Fault number.
If required, the significance of this new fault can be read about in a more recent description
of the control unit.
Remedy:
- replace the firmware on the sensor module by an older firmware version (r0148).
- upgrade the firmware on the control unit (r0018).
232905
<location>Encoder 2: Parameteriz. error
Reaction:
A_INFEED: OFF2 (NONE, OFF1)
SERVO: ENCODER (DCBRAKE, NONE, OFF1, OFF2, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY
Cause:
A parameter of encoder 2 was detected as being incorrect.
It is possible that the parameterized encoder type does not match the connected encoder.
The parameter involved can be determined as follows:
- determine the parameter number using the fault value (r0949).
- determine the parameter index (p0188).
Fault value (r0949, decimal):
Parameter number.
Remedy:
- check whether the connected encoder type matches the encoder that has been
parameterized.
- correct the parameter specified by the fault value (r0949) and p0188.
232920
<location>Encoder 2: Temperature sensor fault
Reaction:
NONE
Acknowledge:
NONE
Cause:
When evaluating the temperature sensor, an error occurred.
Alarm value (r2124, decimal):
1: Wire breakage or sensor not connected (KTY: R > 1630 Ohm).
2: Measured resistance too low (PTC: R < 20 Ohm, KTY: R < 50 Ohm).
Remedy:
- check that the encoder cable is the correct type and is correctly connected.
- check the temperature sensor selection in p0600 to p0603.
- replace the sensor module (hardware defect or incorrect calibration data).
232999
<location>Encoder 2: Unknown alarm
Reaction:
NONE
Acknowledge:
NONE
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-765

Advertisement

Table of Contents
loading

Table of Contents