08/2005
Reactions:
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Protection zone can be traversed after a new NC Start.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
10701
Channel %1 block %2 channel-specific protection zone %3 violated during auto-
matic or MDA mode
Parameters:
%1 = Channel number
%2 = Block number
%3 = Protection zone number
Definitions:
The workpiece-related channel-specific protection zone has been violated. Note that
another tool-related protection zone is still active. The workpiece-related protected area
can be traversed after a new NC Start.
Reactions:
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Protection zone can be traversed after a new NC Start.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
10702
Channel %1 NCK protection zone %2 violated during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
Definitions:
The workpiece-related NCK protection zone has been violated. Note that another tool-
related protection zone is still active. The workpiece-related protected area can be tra-
versed after a new NC Start.
Reactions:
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Remedy:
Protection zone can be traversed after a new NC Start.
Program Con-
Alarm display showing cause of alarm disappears. No further operator action necessary.
tinuation:
10703
Channel %1 channel-specific protection zone %2 violated during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
Definitions:
The workpiece-related channel-specific protection zone has been violated. Note that
another tool-related protection zone is still active. The workpiece-related protected area
can be traversed after a new NC Start.
Reactions:
- Local alarm reaction.
- Interface signals are set.
- Alarm display.
Remedy:
Protection zone can be traversed after a new NC Start.
Program Con-
Alarm display showing cause of alarm disappears. No further operator action necessary.
tinuation:
10704
Channel %1 block %2 protection zone monitoring is not guaranteed
© Siemens AG, 2005. All rights reserved