Siemens SINUMERIK 840D sl Series Diagnostics Manual page 425

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Remedy:
Check the S7 PROFIBUS configuration. Enter the module in the NCK MD.
Program Con-
Switch control OFF - ON.
tinuation:
27223
PROFIsafe: NCK F module MD %1[%2] is not a %3 module
Parameters:
%1 = MD name
%2 = MD array index
%3 = Module type
Definitions:
The F module parameterized in the specified NCK MD has not been entered as input/out-
put module in the S7 PROFIBUS configuration.
• %3 = INPUT: NCK F parameterization expects INPUT module
• %3 = OUTPUT: NCK F parameterization expects OUTPUT module
• %3 = IN/OUT: NCK F parameterization expects INPUT or OUTPUT module
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Check the module in the S7 PROFIBUS configuration.
Program Con-
Switch control OFF - ON.
tinuation:
27224
PROFIsafe: F module MD %1[%2] - MD %3[%4]: double assignment of PROFIsafe
address
Parameters:
%1 = MD name 1
%2 = MD array index 1
%3 = MD name 2
%4 = MD array index 2
Definitions:
In the NCK MD or in the S7 F parameters, the same PROFIsafe address has been
parameterized for the F modules parameterized in the specified machine data. Therefore,
no clear communication link is possible between F master and F slave.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Check and correct the S7 F parameterization and NCK MD.
Program Con-
Switch control OFF - ON.
tinuation:
27225
PROFIsafe: slave %1, configuration error %2
Parameters:
%1 = PROFIBUS slave address
%2 = Configuration error
Definitions:
An error occurred during the evaluation of the S7 PROFIBUS configuration for the speci-
fied slave. This is further specified in alarm parameter %2.
%2 = PRM header: the PRM telegram for this slave could not clearly be interpreted.
Reactions:
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms