Siemens SINUMERIK 840D sl Series Diagnostics Manual page 177

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
Remedy:
Read out the part program, modify it with a text editor (e.g., insert blanks or comments
before the displayed block), so that after reading it in again the part program has a differ-
ent structure in the memory.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
14005
Channel %1 block %2 program %3 program-specific start disable has been set
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions:
Program %3 cannot be executed, as the program-specific start disable has been set for
this file.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Reset the program-specific start disable for file %3.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14009
Channel %1 block %2 illegal program path %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program path
Definitions:
The part program command CALLPATH was called with a parameter (program path)
referring to a directory which does not exist in the file system of the NCK.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
• Modify the CALLPATH instruction such that the parameter contains the complete path
name of the loaded directory.
• Load the programmed directory in the file system of the NCK.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14010
Channel %1 block %2 invalid default parameter in subroutine call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In a subroutine call with parameter transfer, parameters have been omitted that cannot be
replaced by default parameters (call-by-reference parameters or parameters of type
AXIS. The other missing parameters are defaulted with the value 0 or with the unit frame
in the case of frames).
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
The missing parameters must be provided with values in the subroutine call.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14011
Channel %1 block %2 program %3 not existing or will be edited
Parameters:
%1 = Channel number
%2 = Block number, label
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-177

Advertisement