08/2005
G05, G08, G22, G23, G27, G28, G29, G30, G50.1, G51.1, G72.1, G72.2 functions (ISO
mode) also execute subroutine calls. Only one macro or cycle call can appear in an NC
block.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Deactivate modal cycles or modal macro calls if one of the above mentioned G functions
has been programmed.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12724
Channel %1 block %2 no radius programmed for cylinder interpolation activa-
tion/deactivation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When programming G07.1 (cylinder interpolation TRACYL), no cylinder radius has been
programmed. Selection of the cylinder interpolation (TRACYL) with G07.1 C <cylinder
radius> deselect with G07.1 C0. For "C" the name of the rotary axis defined in the TRA-
CYL machine data has to be programmed.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
G07.1 block, program the cylinder radius under the name of the rotary axis for the cylinder
interpolation.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12726
Channel %1 block %2 illegal plane selection with parallel axes
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In a block with plane selection (G17 _ G19), a basic axis of the coordinate system must
not be programmed together with the parallel axis assigned to it.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
For plane selection with G17, G18, G19 either program the basic axis of the coordinate
system or the assigned parallel axis.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12728
Channel %1 block %2 distance for double turret not set
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool clearance for the double turret head in the setting data
$SC_EXTERN_DOUBLE_TURRET_DIST is 0.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Enter tool clearance for the double turret head in the setting data
$SC_EXTERN_DOUBLE_TURRET_DIST.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation: