Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
4336
Channel %1 orientable toolholder no. %2 for orientation transformation %3 does
not exist
Parameters:
%1 = Channel number
%2 = Number of the orientable toolholder
%3 = Number of the orientation transformation that is to be parameterized with the orient-
able toolholder
Definitions:
The orientable toolholder, with whose data the orientation transformation is to be parame-
terized (see machine data $MC_TRAFO5_TCARR_NO_1/2), does not exist.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Remedy:
Enter a valid tool-carrier number.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
4338
Channel %1 invalid transformation type '%2' in toolholder %3 for orientation trans-
former %4
Parameters:
%1 = Channel number
%2 = Transformer type
%3 = Number of the orientable toolholder
%4 = Number of the orientation transformation that is to be parameterized with the orient-
able toolholder
Definitions:
The parameters of the orientation transformation are taken over from the data of an ori-
entable toolholder. This orientable toolholder contains an invalid transformation type.
(Types T, P and M are permissible).
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Remedy:
Enter a valid transformation type.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
4340
Channel %1 block %2 invalid transformation type in transformation no. %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Transformation number
Definitions:
An invalid, i.e. undefined, number was entered in one of the machine data
TRAFO_TYPE_1 ... TRAFO_TYPE_8. This alarm also occurs if a certain type of transfor-
mation is only impossible on the type of control used (e.g. 5-axis transformation on a
SINUMERIK 802D).
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm at block end.
Remedy:
Enter a valid transformation type.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-55