08/2005
Remedy:
Change the table number in the program instruction or define the curve table with the
desired table number.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
18202
Channel %1 block %2 curve table: instruction CTABEND without CTABDEF not
allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The CTABEND instruction, which is used to terminate the definition, has been pro-
grammed in the program without starting a curve table definition with CTABDEF, or the
CTABDEF and CTABEND instructions were not programmed in the same program level.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Remove the CTABEND command or add the CTABDEF( ..) command at the appropriate
program location. The CTABDEF and CTABEND instructions must be programmed in the
same program level (main or subprogram). Start the program again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
18203
Channel %1 block %2 curve table: instruction CTABDEF not within CTABDEF
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the program, the instruction CTABDEF that starts the definition of curve tables, is pro-
grammed within the definition part of a curve table. This is not allowed, as the current
curve table must be completed with CTABEND first.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Remove command CTABEND from program or insert instruction CTABDEF ( ..) in the rel-
evant program position. Instructions CTABDEF and CTABEND must be programmed in
the same program level (main program or subroutine). Restart the program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
18204
Channel %1 block %2 curve table: instruction SUPA not within CTABDEF
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
G code SUPA is not allowed for the definition of a curve table, as it triggers a preprocess-
ing stop.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Remove G code SUPA from the curve table definition. If possible, use G codes G53 or
G153 instead of SUPA.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
© Siemens AG, 2005. All rights reserved