14700
Channel %1 block %2 timeout during command to interpreter
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A timeout has occurred in control-internal commands such as ANWAHL (part program
selection), RESET (channel reset), REORG (reorganization of the preprocessing buffer)
and NEWCONFIG (change in the configuration-specific machine data = warm restart).
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. If the runtime error occurred
as the result of a temporary excessive load on the system (e.g. in the MMC area or in
OEM application) error-free execution is possible on repeating the program or operator
action. Otherwise, the A&D MC system support should be contacted with a precise
description of the error situation:
(contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.:see alarm
1000)
Program Con-
Switch control OFF - ON.
tinuation:
14701
Channel %1 block %2 number of available NC blocks reduced by %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of non-available blocks
Definitions:
After reset, it has been found that the number of available blocks has decreased com-
pared with the last reset. This is due to a system error. Part program execution can be
resumed after the alarm has been acknowledged. If the number of blocks no longer avail-
able is less than 28060 MM_IPO_BUFFER_SIZE, then the POWERON alarm 14700 is
output.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Proceed as in the case of a system error.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
14710
Channel %1 block %2 error in initialization sequence in function %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Identifier of the function which caused the error
Definitions:
Initialization blocks are generated (or not) after control power-up, program reset and pro-
gram start, depending on the settings in machine data $MC_RESET_MODE_MASK and
$MC_START_MODE_MASK.
Errors can occur because of incorrect machine data settings. The errors are output with
the same error messages as appear if the function was incorrectly programmed in the
part program.
This alarm is generated in addition, in order to indicate that an error refers to the initializa-
tion sequence.
Parameter %3 specifies which function triggers the alarm:
Control power-up and (program) RESET:
Value:
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms
2-225