Overview of Alarms
- Interface signals are set.
- Alarm display.
Remedy:
Program the lifting direction under ALF=... within the permissible limits.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
16005
Channel %1 block %2 invalid value for lifting distance
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Mistake in programming: the value for the lifting path must not be negative.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
16010
Channel %1 block %2 machining stop after lift fast
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
LIFTFAST without interrupt routine (Asup) has been programmed. The channel is
stopped after the lift motion has been carried out.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
After the channel stop, the axes must be retracted manually in JOG and the program
aborted with Reset.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
16015
Channel %1 block %2 wrong axis identifier %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
Axis names from different coordinate systems were used to program axes for LIFTFAST.
The retraction movement is no longer clear.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Use axis names from one coordinate system.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
16016
Channel %1 block %2 no retraction position programmed for axis %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
The retraction enable was programmed for LIFTFAST without defining a retraction posi-
tion for the axis. The retraction movement is no longer clear.
Reactions:
- Correction block is reorganized.
2-256