Overview of Alarms
- Alarm display.
Remedy:
Modify definition file or initialization file
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15187
Channel %1 error during execution of PROGEVENT file %2.
Parameters:
%1 = Channel number
%2 = PROGEVENT file name
Definitions:
An error has occurred on executing PROGEVENT.
The name of the program that was started as PROGEVENT is displayed with alarm
15187. Alarm 15187 is displayed together with the alarm that describes the error cause.
Alarm 15187 is also output
when the alarm occurs in a subroutine started from PROGEVENT.
Reactions:
- Interface signals are set.
- Alarm display.
Remedy:
Correct the PROGEVENT file (subroutine).
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
15188
Channel %1 error during execution of ASUB file %2.
Parameters:
%1 = Channel number
%2 = ASUB file name
Definitions:
An error has occurred on executing an ASUB.
Alarm 15188 displays the name of the program that was started
as ASUB. Alarm 15188 is output together with the alarm that
describes the error cause. Alarm 15188 is also output when
the alarm occurs in a subroutine started from the ASUB.
Reactions:
- Interface signals are set.
- Alarm display.
Remedy:
Correct the ASUB file (subroutine).
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
15190
Channel %1 block %2 not enough free memory for subroutine call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following deadlock has been found in the interpreter: Memory is needed for calling a
subroutine. The module memory is, however, empty and there is no prospect of module
memory becoming free again by executing the preprocessing/main run queue, because
this queue is empty.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Please inform the authorized personnel/service department. Increase machine data
28010 MM_NUM_REORG_LUD_MODULES/28040 MM_LUD_VALUES_MEM / 18210
MM_USER_MEM_DYNAMIC or program a preprocessing stop STOPRE before calling
the subroutine.