Siemens SINUMERIK 840D sl Series Diagnostics Manual page 94

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

Overview of Alarms
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy:
Press RESET and select the mode again.
Program Con-
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
tinuation:
10250
[up to SW 3.x only] Channel %1 reorganization of block processing not possible at
this time
Parameters:
%1 = Channel number
Definitions:
REORG is not possible at present.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
--
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10251
[up to SW 3.x only] Channel %1
Parameters:
%1 = Channel number
Definitions:
REORG is not possible at present.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Press RESET.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10252
[up to SW 3.x only] Channel %1 reorg sequence canceled
Parameters:
%1 = Channel number
Definitions:
Internal sequence error. REORG is not possible at present.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Press RESET.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
10253
[up to SW 3.x only] Channel %1 reorg sequence canceled
Parameters:
%1 = Channel number
Definitions:
Internal sequence error. REORG is not possible at present.
Reactions:
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy:
Press RESET.
2-94
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005