Overview of Alarms
• T function replacement by D function programming in the same part program line is not
possible with active TLC (G43/G44) in ISO2 system.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
An M or T function replacement is only possible if a subprogram call or return jump has
not already been performed as a result of other program constructs. The part program
must be corrected accordingly.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14017
Channel %1 block %2 syntax error when calling the subroutine via M function
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When calling M code subroutine with parameter transfer, an illegal syntax was detected:
• Address extension not programmed as a constant.
• M function value not programmed as a constant.
Note: If a parameter transfer has been programmed via MD
$MN_M_NO_FCT_CYCLE_PAR for an M function replacement, the following restriction
applies to this M function: both the address extension and the M function value must be
programmed for replacement as constants.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Change the programming of the M function.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14018
Channel %1 block %2 parts program command %3 not executable (protection level
setpoint value: %4 actual value: %5)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Programmed command
%4 = Protection level of the command / current protection level
Definitions:
To parts program command %3, a protection level has been assigned that is logically
higher (smaller in value) than the current access right, or the command does not exist in
the current control configuration.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify parts program. Please see the Siemens Progamming Guide or OEM documenta-
tion for the language commands permissible for the relevant system configuration.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14020
Channel %1 block %2 wrong value or wrong number of parameters on function or
procedure call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
• An illegal parameter value was specified in a function or procedure call.
• An illegal number of actual parameters was programmed in a function or procedure call.
Reactions:
- Correction block is reorganized.
2-180
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition