Overview of Alarms
Definitions:
When oscillating controlled by synchronized actions, the assignment of oscillating and
infeed axis (OSCILL) as well as the definition of the infeed (POSP) must be carried out in
one NC block.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14033
Channel %1 block %2 involute: no end point programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No end point was programmed for the involute. This is either possible via direct program-
ming with the geometry axis identifiers or by specifying the angle between start and end
vector.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14034
Channel %1 block %2 involute: angle of rotation too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With programming of the angle of rotation (with AR) for involute interpolation, the maxi-
mum programmable angle of rotation is limited if the involute is moving towards the basic
circle. The maximum value is reached if the involute touches the basic circle. With
MD_INVOLUTE AUTO_ANGLE_RESTRICTION = TRUE, each angle is accepted without
an alarm; if necessary, the angle is automatically limited during interpolation.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14035
Channel %1 block %2 involute: start point invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, the start point of the involute must be outside the basic circle.
The programmed center point or radius must be adapted accordingly.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14036
Channel %1 block %2 involute: end point invalid
Parameters:
%1 = Channel number
2-182