Siemens SINUMERIK 840D sl Series Diagnostics Manual page 155

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents

Advertisement

08/2005
because the space-dependent assignment has been lost on account of the omitted axis
parameters.
Axes that can be omitted and following parameters do not occur in the predefined proce-
dures and functions.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. In predefined
procedures and functions either remove the following parameters or transfer any preced-
ing axis parameters. In user-defined procedures and functions, parameter transfer must
be programmed in accordance with the instructions given in the machine manufacturer's
programming guide.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12360
Channel %1 block %2 dimension of parameter %3 incorrect
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
The following possibilities of error must be checked:
• The current parameter is an array, but the formal parameter is a variable
• The current parameter is a variable, but the formal parameter is an array
• The current and formal parameters are arrays, but not with the dimensions to be
defined.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. Correct the NC
part program in accordance with the cause of error as listed above.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12370
Channel %1 block %2 range of values %3 not permissible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
A variable has been initialized with a value range outside an initialization block. The defi-
nition of program-global variables is allowed only in special initialization blocks. These
variables can be initialized with a value range.
Reactions:
- Correction block
- Interface signals are set.
- Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Remove the value range specification (begins with the keyword OF) or define the variable
as a global variable in the initialization block and initialize it with a value range.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
12380
Channel %1 block %2 maximum memory capacity reached
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Overview of Alarms