Overview of Alarms
Definitions:
An error has occurred in compile mode. The (compiler) error message refers to the pro-
gram specified here.
Reactions:
- Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
15171
Channel %1 block %2 compiled program %3 older than the relevant subroutine
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Compiled program file name
Definitions:
When calling a precompiled subroutine, it was noticed that the compiled program is older
than the relevant SPF file. The compiled program was deleted and during start the sub-
routine is executed instead of the compiled program.
Reactions:
- Correction block is reorganized.
- Interface signals are set.
- Alarm display.
Remedy:
Perform another precompilation.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
15172
Channel %1 block %2 subroutine %3. No interface available at time of preprocess-
ing.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Subroutine name
Definitions:
In compilation mode no program interface of the subroutine to be called was available at
the time of pre-compilation.
Reactions:
- Interpreter stop
- Interface signals are set.
- Alarm display.
Remedy:
Modify parts program or recreate program interfaces and pre-compile programs again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15173
Channel %1 block %2 variable %3 was unknown at the time of preprocessing.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Variable
Definitions:
At the time of program precompilation, variable %3 was not known to the control.
Reactions:
- Interpreter stop
- Interface signals are set.
- Alarm display.
Remedy:
Correct the part program or introduce the variable at the time of precompilation, i.e. acti-
vate the new GUD variable prior to precompilation. Then restart precompilation.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
15175
Channel %1 block %2 program %3. Interfaces could not be built
Parameters:
%1 = Channel number
%2 = Block number, label
2-246
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved