Overview of Alarms
- Channel not ready.
Remedy:
Please inform the authorized personnel/service department.
• Modify MD 1107: $MD_INVERTER_MAX_CURRENT (transistor limit current)
• Check the motor data (motor code)
• Check the controller data, current/speed controller gain too high
• Reduce MD 1145: $MD_STALL_TORQUE_REDUCTION (stall torque reduction factor).
• Check the power section and motor terminals (including motor protection), possibly
power section too small
• Increase MD 1254: $MD_CURRENT_MONITOR_FILTER_TIME (time constant for cur-
rent monitoring)
• Error in actual current measurement (if necessary, replace 611D power section or con-
troller module)
• If rotor position identification is active, check MD 1019
$MD_CURRENT_ROTORPOS_IDENT (current for rotor position identification) and, if
necessary, reduce the setting.
Program Con-
Switch control OFF - ON.
tinuation:
300502
Axis %1 drive %2 maximum current monitoring of phase current R
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The phase current R is greater than or equal to 1.05 times the maximum power section
current MD 1107: $MD_INVERTER_MAX_CURRENT (transistor limit current).
Reactions:
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy:
Please inform the authorized personnel/service department.
• Check max. power section current in MD 1107 $MD_INVERTER_MAX_CURRENT
(transistor limit current)
• Check the motor data (motor code)
• Motor has ground or winding fault
• Check the controller data
• Check the power section and motor terminals (including motor protection)
• Error in actual current measurement (if necessary, replace 611D power section or con-
troller module)
Program Con-
Switch control OFF - ON.
tinuation:
300503
Axis %1 drive %2 maximum current monitoring of phase current S
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The phase current S is greater than or equal to 1.05 times the maximum power section
current MD 1107: $MD_INVERTER_MAX_CURRENT (transistor limit current).
Reactions:
- Mode group not ready.
- The NC switches to follow-up mode.
- Channel not ready.