Overview of Alarms
- Interface signals are set.
- Alarm display.
- Alarm reaction delay is canceled.
Remedy:
Set the required option bit or delete the .elf file from the Flash File System.
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
7205
Incompatible OEM transformation channel %1 version NCK %2 CC %3
Parameters:
%1 = (int) channel number
%2 = Transformer interface version NCK
%3 = Transformer interface version OEM
Definitions:
The interface for OEM transformations has changed incompatibly in the system.
Reactions:
- NC not ready.
- Channel not ready.
- Interface signals are set.
- Alarm display.
- Alarm reaction delay is canceled.
Remedy:
Load the new compile cycle version
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
7500
Block %1 invalid protection level for command %2 (protection level act.: %3 prog.:
%4)
Parameters:
%1 = Block number
%2 = Programmed command
%3 = Current protection level of the command
%4 = Programmed protection level of the command
Definitions:
On assigning a protection level for a parts program command via REDEF command
• an impermissible parts program command has been programmed
• a protection level has been programmed that is logically smaller (larger in value) than
the protection level currently applicable for this command.
• the relevant definition file has not been protected sufficently against write access. The
write protection of the file must be at least as high as the highest protection level that has
been assigned to a parts program command in this definition file.
Reactions:
- Alarm display.
Remedy:
Modify definition files /_N_DEF_DIR/_N_MACCESS_DEF or /_N_DEF_DIR/_N_UAC-
CESS_ DEF. Please see the Siemens Programming Guide or the OEM documentation
for the language commands permissible for the relevant system configurations.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
8000
Channel %1 option 'user interrupt programs' not set
Parameters:
%1 = Channel number
Definitions:
The input signals of NCK inputs are required in order to activate the interrupt routines and
rapid lift from contour. This function is not included in the basic version and must be retro-
fitted when needed.
Reactions:
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
2-82
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005